Apacer Technology AD330 Instrukcja Użytkownika Strona 11

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 19
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 10
Industrial Micro SD Card
AP-MSDxxxIXX-T
10
© 2013 Apacer Technology, Inc. Rev. 1.0
SYMBOL PARAMETER MIN MAX UNIT Note
f
PP
Clock frequency data transfer mode
0 50 MHz
Ccard≤10 pF
(1 card)
t
WL
Clock low time 7 - ns
Ccard≤10 pF
(1 card)
t
WH
Clock high time 7 - ns
Ccard≤10 pF
(1 card)
t
TLH
Clock rise time - 3 ns
Ccard≤10 pF
(1 card)
t
THL
Clock fall time - 3 ns
Ccard≤10 pF
(1 card)
t
ISU
Input setup time 6 - ns
Ccard≤10 pF
(1 card)
t
IH
Input hold time 2 - ns
Ccard≤10 pF
(1 card)
t
ODLY
Output delay time 14 ns
CL40 pF
(1 card)
T
OH
Output hold time 2.5 50 ns
CL15 pF
(1 card)
C
L
System capacitance of each line* 40 pF
CL15 pF
(1 card)
*In order to satisfy severe timing, host shall run on only one card
4.2 Bus Interface Timing (High-speed)